  reset saved-configuration

  The saved configuration file will be erased. Are you sure? [Y/N]: y // 提示是否擦除配置文件

  Configuration in the device is being cleared.

  Please wait ...

  ...

  Configuration in the device is cleared.

   reboot

  This command will reboot the system. Since the current configuration may have been changed, all changes may be lost if you continue. Continue? [Y/N] Y // 提示是否重启设备,按Y将重新启动

  【提示】擦除配置文件后,必须要重启设备后才能恢复到出厂设置。

  H3C交换机查看光功率收发光命令

  [H3C]_hidecmd

  Now you enter a hidden command view for developer's testing, some commands may

  affect operation by wrong use, please carefully use it with our engineer's

  direction.

  [H3C-hidecmd]_display transceiver ?

  diagnosis Diagnostic information

  interface Display by interface

  register Register information

  [H3C-hidecmd]_display transceiver diagnosis interface GigabitEthernet 1/0/25

  GigabitEthernet1/0/25 transceiver diagnostic information:

  Current diagnostic parameters:

  Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)

  54 3.41 17.65 -7.45 -5.85

  Alarm thresholds:

  Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)

  High 85 3.70 65.00 0.97 0.97

  Low -10 2.90 10.00 -40.00 -13.01

  Parameters when first used on 2000.4.26:

  Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)

  39 3.41 16.35 -7.21 -5.85

  Total account of alarms: 15

  Latest occurrence of different alarms:

  Type Date Description

  Temp N/A N/A

  Voltage N/A N/A

  Bias N/A N/A

  RX power 2014.04.09 RX power low

  TX power N/A N/A

  TX N/A N/A

  RX N/A N/A

  OTHER N/A N/A

  Latest three alarms:

  Date Description

  2014.04.07 RX power low

  2014.04.09 RX power low

  2014.04.09 RX power low

  以下是端口没有插上模块的:

  [H3C-hidecmd]display transceiver diagnosis interface GigabitEthernet 1/0/27

  Error: The transceiver is absent.

  [H3C-hidecmd]display transceiver diagnosis interface GigabitEthernet 1/0/28

  Error: The transceiver is absent.

  USB是主从模式的,一般意义上,PC被定义为主设备,提供5V电压,如果两边都是PC,由于供电线需要构成一个本地回路才能工作,这就可能烧毁主板,关键就是供电回路问题。我是怎么做到USB线联网呢?我是在淘宝上买了一根特殊的USB线,具体怎么实现的没有深究,无外乎接地反转之类的。

  USB主从模式的初衷是为了将外设这类从设备连接到主机这种庞然大物主设备上,然而正如你看到的那样,目前的情况是,庞然大物已经越来越少,桌面PC被使用的越来越少,更多的是同样大小的小型设备,手机,平板,....好多年前,以太网的双绞线也有本地回路问题(烧不毁板子,只是脉冲无法发送和接收,双绞线没有单独的供电线,电压随着脉冲发生,因此为了构成回路,线的一端发送脉冲,另一端必须接收脉冲),因此那时规定,连接同种设备需要交叉线,即1-3,2-6线序对调(详见568A,568B标准),可是后来在PHY层实现了自动协商,不管交叉线还是直连线都可以用于任何支持自协商的网卡了。USB的问题在于,你加入了主从的约束,就少了通用性。实际上任何事情,加入一点约束,就会丧失一点通用性。